The main function
The UV-accelerated aging test chamber uses imported UVA-340 fluorescent UV light as a light source to simulate the damage caused by sunlight, rain and dew. The UV weatherproof box uses a fluorescent UV lamp to simulate the effect of sunlight, and uses condensed moisture to simulate dew.
The material to be tested is placed in a cyclical program of alternating light and moisture at a certain temperature to accelerate the weathering test of the material to obtain the weather resistance of the material. The UV box can reproduce the hazards of outdoor months or years in days or weeks. Types of hazards include: fading, discoloration, loss of light, powdering, cracking, turbidity, air bubbles, embrittlement, strength, decay, and oxidation. This machine contains a shower device.
Applicable industries:
It is widely used in paint, resins, plastics, rubber,printing and packaging, aluminum, adhesives, auto, cosmetics, metals, electronics, electroplating, medicine, etc.
In line with international standards:
ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE, J2020, ISO 4892 All current UV aging test standards.
Light source:
The light source uses 8 imported UV fluorescent lamps with a rated power of 40W as the light source. Ultraviolet fluorescent tubes are distributed on both sides of the machine, 4 on each side.
There are UVA-340 and UVB-313 light sources for users to choose from. The luminescence spectrum energy of the UVA-340 lamp is mainly concentrated at the wavelength of 340 nm, and the luminescence spectrum of the UVB-313 lamp is mainly concentrated near the wavelength of 313 nm.
We use UVA-340 lamps because the fluorescent light energy output will gradually decay with time. In order to reduce the impact of the test due to the attenuation of light energy, this test chamber is 1/4 of all eight lamps. In the life of a fluorescent lamp, an old lamp is replaced by a new lamp, so that the ultraviolet source is always composed of a new lamp and an old lamp, thereby obtaining a constant output of light energy. The effective life of the lamp can be 1600 hours
Technical parameter
Model | HY-1020 | HY-1021 |
Studio Size | W1170*H450*D500mm | W1150 X H400 x D400mm |
Outside dimension | W1300×H550×D1480mm | W1400 X H1450 x D650mm |
Temperature range | RT+10~70°C | |
Temperature uniformity | ±2°C | |
Temperature fluctuation | ±0.5°C | |
Wavelength ultraviolet light | UV-A: 315-400nm; UV-B: 280-315nm (8pcs, 1600h lifetime) | |
Testing time | 0~999H, adjustable | |
Materials | Inside and Outside SUS#304 stainless steel | |
Humidity range | ≥90%RH | |
Lamp power | 40W/Piece | |
Irradiance | 1.0W/m2 | |
Distance from sample to lamp | 50±2mm (adjustable) | |
Power | 220V/50Hz /±10% 4.5KW |