• Environmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test Machine
  • Environmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test Machine
  • Environmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test Machine
  • Environmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test Machine
  • Environmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test Machine

Environmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test Machine

After-sales Service: 12 Months
Certification: CE
Warranty: 1 Year
Hatching Rate: 98%
Use Voltage: 220V-240V
Material: Special Plastic
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
B-CY-120
Package
Wooden Case
Transport Package
Sea Ship, Air Ship
Specification
Medium
Trademark
BOTO
Origin
China
Production Capacity
5000 Months/Mouth

Product Description

Ozone Aging Test Chamber Environmental Test Chambers Lab Machine GB/T7762-2008 Test Machine

 

Description:

Ozone is present in very small amounts in the atmosphere, but is a major factor in rubber cracking.

Ozone aging chamber is to simulate and enhance the ozone environment in the atmosphere. Studied the effect of ozone on rubber, fast identification and evaluation of rubber ozone aging resistance and antiozonant shielding efficiency of the method, and then take effective measures, the anti aging in order to improve the service life of rubber products.

This series of products are suitable for nonmetallic materials, organic materials (coating, rubber, plastic, paint, pigment, etc.) under the condition of ozone aging test.

Ozone resistance aging test box is mainly suitable for polymer materials and products (rubber) of the resistance to ozone aging performance test. Ozone content in the atmosphere is very low, but it is the main factors of polymer materials aging. Ozone aging test chamber simulating and strengthen the ozone condition in the atmosphere, get approximate to actual use or reproduction of the test results in a short time. The studay of ozone effect regulation to rubber products, quickly identify and evaluate rubber materials resistance to ozone and antiozonant protection efficiency method,and then take effective aging proof measures to improve the service life of rubber products.
Environmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test Machine

Sample rack requirements:

1. It is composed of shell, electronic components and ozone generator.

 

2. At the required elongation, the fixture is used to fix both ends of the sample. When contacting with the ozonated air, the length direction of the sample should be basically parallel to the direction of the air flow.

 

3. The fixture should be made of materials (such as aluminum) that are not easy to decompose ozone.

 

4, make the sample rotation speed between (20^-25) mm/s, in a vertical dry air plane, each sample continuously along the same path.

 

5. The rotation time of one sample is (8^-12) min. The scanning area of the sample (the shaded part shown in Figure 2) is at least 40% of the effective area of the test chamber.

 

6. Sample preparation shall comply with the provisions of GB/T 9865.1. The sample is best cut from the new molded test piece, if necessary, from the finished product. 

 

7. At least 3 samples should be used for each test condition.

 

8. The width of the standard strip sample shall be no less than 10mm, and the thickness shall be 2.Omm 0.2mm. The length of the sample between the two ends of the fixture shall be no less than 40mm before stretching.

product description:

 


Model
B-CY-120 B-CY-250 B-CY-500 B-CY-1000

Internal Dim(DxWxH)
45x45x60 50x60x75 70x80x90 100x100x100
 Temperature range 0ºC-70ºC
Humidity range >65%R·H

Ozone concentration
0-200PPm.0-300PPm

Temperature fluctuation
±0.5ºC

test apparatus

Dynamic and static (optional)

Sample rack rotation speed

360 degree rotating sample holder (1 rpm per minute)

Gas flow rate
12-16mm/s

Temperature Controller

Imported LED digital display P.L. D+5.5, R microcomputer integrated controller

Time controller

Precision hours,minutes,seconds time controller

Ozone concentration analysis

Imported concentration analysis regulator 4-20mA outputs,RS232 communication port

Ozone generator

Silent discharge tube type

Security protection

Leakoge,short circuit,over temperature,motor overheating.over-current protection

Environmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test MachineEnvironmental Ozone Aging Test Chamber GB/T7762-2008 Lab Test Machine



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 9000, ISO 14064, GMP, BSCI, SA 8000, IFS
Export Year
2021-08-26