Basic Info.

Model NO.
B-TH-120
Certification
CE, TUV, ISO
Warranty
3 Years
Temperature Range
-70ºC~+150ºC
Transport Package
Strong Wooden Case
Specification
1000L
Trademark
BOTO
Origin
China
HS Code
85141090
Production Capacity
60000sets /Month

Product Description

Principle:
The temperature humidity test machine adopts Chinese and English touch screens, multiple sets of PID control functions, and RS-232C / 485C connected to the computer interface control. It can simulate different environmental conditions such as high temperature, high humidity, low temperature, high humidity, low temperature, low humidity, high temperature, and low temperature. It is also equipped with a highly accurate programming control and fixed-point control system that is easy to operate and learn. It is being identified and translated online.


Test accuracy:
1,GB2423.1-2008/IEC6008-2-1-2007
2,GB/T 2423.2-2008
3,GJB150.3A-2009
4,GJB150.4A-2009
5,GB2423.22-2008
6,GBT 2424.5-2006
7,GB/T 10589-2008
8,GB/T2423.3-2008(IEC68-2-3)


Specification:

1. The separation of humidifier circuit from electric circuit improves safety and protects the circuit against the leakage of water supply line.

2. Available in Chinese and English LCD touch screen, easy operation and program.

3. Programmable temperature humidity test chamber is able to display the relative date and information of the whole operating system in running mode, graphic display. Precautions, maintenance and troubleshooting appear on the screen instantly.

4. The Sirocco fan motor provides greater cyclic airflow to avoid dead corner in the chamber so as to obtain an uniform distribution of temperature and humidity.

5. The system of heating up, heating down, dehumidifying, and humidifying can be operated independently so as to reduce the cost of testing, extend the operating life of the machine and decrease the failure rate.

6. Water Supply adopts automatic watering System, Circulating water supply together with water filter.



Features:
Model BT-1000K20 BT-1000K40 BT-1000K70
Capacity 1000L
Internal dimensions 1000mm*1000mm*1000mm(W*H*D)
External dimensions 1250mm*2000mm*1910mm(W*H*D)
Temperature Range -20ºC ~ + 150ºC -40ºC ~ + 150ºC -70ºC ~ + 150ºC
Humidity Range 20%~98%RH                            
Temperature resolution 0.01ºC 
Humidity resolution 0.1%R.H
Temperature deviation ±0.5ºC
Humidity deviation ±2%R.H
Temperature uniformity <= 2ºC
Humidity uniformity ±3%R.H
Temperature fluctuation ±0.5ºC
Humidity fluctuation ± 2%R.H
Heating rate -70ºC → + 150ºC, >= 3ºC / min
Cooling rate 150ºC → -70ºC, >= 1ºC / min
Humidification system Stainless steel humidifier
Heating system Nickel chromium alloy stainless steel heater
Water supply system Front-mounted water supply tank, automatic water supply system
Controller Taiwan Visuo Controller
Case shell High-quality cold-rolled steel plate electrostatic spray (1.2mm thick)
Chassis inner wall SUS304 # stainless steel plate (1.2mm thick)
Insulation material 100mm polyurethane rigid foam + 100mm high density glass fiber cotton
Standard configuration φ50 test hole, lighting lamp, double-layer vacuum strengthened glass observation window.
Weight About 700kg
Electric current 40A 45A
P ower 13.5kw 16kw
Power supply Three-phase, 380V
Safety protection measures The overall equipment is over temperature, the fan is overheated, the overall equipment is under-phase / reverse-phase, the refrigeration system is overloaded, the refrigeration unit is over-pressured, the overall equipment timing, leakage, operation indication, automatic shutdown after failure alarm, etc.
Refrigeration Compressors Imported French Taikang fully enclosed compressor
Refrigerant Environmental protection refrigerant R404A / R23
Cooling method Single-stage cooling Mechanical binary refrigeration
Blower Centrifugal fan with forced circulation
Evaporator Finned tube heat exchanger
Condensation method Air-cooled
Condenser Air-cooled scale condenser, cooling fan cooling Stainless steel brazed plate heat exchanger
Filter drier Absorbs residual moisture and acidic substances in the refrigerant of the refrigeration system, and filters out solid rest particles and copper shavings in the system to protect the normal operation of the expansion valve and capillary from ice and dirty plugging
 
Control System
Screen display function 1. Temperature and humidity setting (SV) actual (PV) value is displayed directly
2. Can display the execution program number, segment, remaining time and cycle number, running time display
3. Program editing and graphic curve display
4. With a separate program editing screen, each page can enter 4 segments of temperature and humidity, time
5. Fixed point or program action status display
6. Language conversion can switch Chinese / English
7.7 inch true color display screen
Program capacity and control function 1. Program quantity that can be used: maximum 120 groups, 1 program can be composed of 1 ~ 99 stages, capacity: 1200 stages
2. Commands can be executed repeatedly: each command can be up to 999 times, the temperature and humidity slope can be set by the time axis; 3. The program can be set to connect to use; the production of the program is easy to use conversational operation; with editing, Clear, insert and other functions; group time signal output control (can control the ON / OFF action of the test object)
4. With 9 groups of PID parameter settings
5. With skipping and holding functions during program execution
6. With power-off program memory, it can automatically start and resume the program after power is restored
7. Data acquisition, export, view graphics function
8. PID automatic calculation and FUZZY control function
9. The screen can be adjusted for backlight, and the backlight time can be set
10. On-screen display protection function can be set to close regularly or manually
11. Program copy, COPY, connection function, edit experiment title and other program editing functions
12. With appointment start and shutdown function
13. With date and time adjustment function
14. Button and screen lock (LOCK) function
15. Standby picture viewing function and exception handling picture explanation function
Communication interface 1.R232 / 485 communication
2. Can display curves and obtain data
3. Can be used as a monitoring and remote control system
Setting method Chinese / English interface, touch input
Operation mode Program method / fixed value method
Predetermined area Maximum temperature range: 5 ºC
Display resolution Temperature:0.01ºC;Time:0.1min
Power off memory function Can set power failure recovery mode as: hot start / cold start / stop
Input Platinum resistance
Storage function Standard configuration 2G SD card to record test data curve, can upload and download data, expand storage capacity


Programmable Temperature Humidity Test Chamber

Programmable Temperature Humidity Test Chamber
Programmable Temperature Humidity Test Chamber
Programmable Temperature Humidity Test Chamber
Programmable Temperature Humidity Test Chamber

Programmable Temperature Humidity Test ChamberProgrammable Temperature Humidity Test Chamber
Programmable Temperature Humidity Test ChamberProgrammable Temperature Humidity Test ChamberProgrammable Temperature Humidity Test ChamberProgrammable Temperature Humidity Test Chamber
Programmable Temperature Humidity Test Chamber


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier