MIL-2164A-19 Environmental Test Chambers Rapid Temperature Test Chamber ISO Program Setting
Rapid temperature change test chamber refrigeration system and compressor:
In order to ensure the cooling rate of the test chamber and the minimum temperature requirements, the test chamber uses a set of Taikang fully enclosed compressor composed of binary overlapping air cooling refrigeration system. The overlapping refrigeration system consists of a high temperature refrigeration cycle and a low temperature refrigeration cycle, and its connecting vessel is the evaporative condenser. The evaporative condenser also plays the role of energy transfer, transferring the heat energy in the working room through the two-stage refrigeration system to achieve the purpose of long temperature. Refrigeration system design application of energy regulation technology, an effective treatment can ensure that in the normal operation of the refrigeration unit and the refrigeration system of energy consumption and cooling capacity for effective regulation, so that the refrigeration system operating costs and failure rate down to a more economic state.
Application:
This Chamber can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material.
GB/T2423/5170/10586, JIS C60068, ASTM D4714, CNS3625/12565/12566 etc.
1.Use the high precision microcomputer touch temperature and humidity controller with high stability of platinum resistance to temperature and wind speed in the circulatory system of temperature and humidity test.
2. Control temperature&humidity well-distributed, precisely and steady.
3.Completely independent system separate for testing in high temperature, low temperature and constant temperature&humidity environment.
Manufacturer:
Model | dry heat | B-T-80(A-E) | B-T-120(A~E) | B-T-225(A~E) | B-T-504(A~E) | B-T-1000(A~E) |
damp and ho | B-TH-80(A-E) | B-T-120(A~E) | B-T-225(A~E) | B-T-504(A~E) | B-T-1000(A~E) | |
Internal Dim (CM) | 40x50x40 | 45x60x45 | 60x75x50 | 70x90x80 | 100x100x100 | |
External Dim(CM) | 75x203x203 | 75X189X110 | 90X177X130 | 100X180X103 | 130X190X123 | |
Relative Humidity | 20%-98%RH | |||||
Temp Range |
-70ºC~180ºC(100ºC) (A:0ºC B:-20ºC C:-40ºC D:-60ºC E:-70ºC) | |||||
heat-up time | 1ºC-15ºC/min |
|||||
Pull down time | 1ºC-15ºC/min | |||||
Temp Fluctudtiont | ±0.5ºC | |||||
Temp Uniformity | ±1.0ºC | |||||
Temp&Humi.Deviation | ±1.0ºC/±3.0ºCRH | |||||
Interior | SUS#304Stainless steel plate | |||||
Exterior | Coating or SUS#304Stainless steel plate | |||||
Power Source | AV:220V/380V 50/60Hz | |||||
Power(KW) | The technical proposal shall prevail |