Customization: | Available |
---|---|
After-sales Service: | One Year |
Power Supply: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Emperature Humidity Test Chamber Ozone Aging Test Chamber GB/T7762-2008 Manufactrer
Product Description
Ozone aging tank simulation and strengthen the ozone in the atmosphere conditions, studied the effect of ozone on rubber, rapid identification and evaluation of rubber ozone aging resistance and antiozonant shielding efficiency of the method, and then take effective measures, the anti aging in order to improve the service life of rubber products. Ozone aging test chamber for non-metallic materials and rubber products aging crack test.
Test Environmental Conditions
The ambient temperature is +25ºC, relative humidity ≤85% and there is no sample in the test chamber
* The stainless steel test chamber meets the international standard and the completely closed gas loop for producing ozone by silent discharge. The entire ozone gas generation and capture is a closed loop to ensure personal safety.
* arbitrarily set ozone concentration in the range of 1000pphm.
* Sample holder device driven by speed regulating motor
(It satisfies the static tensile test, and the specimen's running trajectory satisfies the cycloidal trajectory principle)
* Ozone concentration automatic digital display control instrument.
* Double beam "QUA" non-dispersive ultraviolet ozone detector.
* Digital display automatic online measurement.
* There is a calibration interface for metrological verification.
* Ozone concentration/temperature and humidity setting value control PID self-setting, convenient and reliable operation.
* 3rd generation Bill Lambert measurement application software.
* Security door lock control system
Architectural Feature:
1.Insulation enclosure:
(1) Outer wall material: A3 steel plate with electrostatic spraying
(2).Inner wall material: mirror stainless steel plate SUS# 304.
(3).Box insulation material: 100mm high temperature resistant rigid polyurethane foam.
(4).Insulation material for box door: 100mm high temperature resistant rigid polyurethane foam.
2.Bottom structural strength:The heavy capacity of track at the bottom of the test box: ≤100Kg/m (load). The bottom plate of the studio is welded with 4mm channel steel.
3. Air conditioning passage Stainless steel long axis centrifugal fan: 1 /90W.
Fan, heater, evaporator (and dehumidifier), drainage device, pressure balance port, adjustable air guide plate, temperature sensor
4.Standard configuration of test box Window 250x350x40mm 3 layers of vacuum toughened glass.
(1).Flush type handle,
(2).Door hinge :SUS #304 inlet hinge
(3).Energy-saving light in the box: LED light emitting way
(4).Lead hole: 50mm 1 (with a rubber plug)
(5).Ozone discharge outlet: 50mm towards outdoor
5.The door is:
(1) Single door, open outwards, hinged on the left, handle on the right (when facing the front of the box).
(2) Equipped with safety lock locking mechanism (the door can be opened in the test room), the door is equipped with electric heating to prevent condensation, and the viewing range of insulating glass observation window is about W200×H280mm.A dew-proof electric heating device is provided for the door frame
6. Control panel Domestic controller TEMI880 professional display screen, ozone aging display screen, device timer (0-99999 hours, non-returnable), overtemperature protection setting device, emergency stop switch, operation indicator, fault indicator, buzzer, USB interface, with USB function, curve and data can be downloaded.
7. Refrigerating unit in the mechanical room, water plate for compressor, pressure discharging device, heating device, standby sample testing power
8. Distribution cabinet switchboard, cooling fan, main power switch, IO board, machine tool transformer, ballast, intermediate relay, time relay, solid state relay, AC contactor, thermal relay, fuse, circuit breaker
9. Heater Finned radiator tube type stainless steel electric heater
(1) Thermal control mode: SSR (solid state relay) contact-free pulse width adjustment
(2).Thermal power: about 2.5KW
Model:
Model |
B-CY-120 | B-CY-250 | B-CY-500 | B-CY-1000 | |
Internal Dim(DxWxH) |
45x45x60 | 50x60x75 | 70x80x90 | 100x100x100 | |
Temperature range | 0ºC-70ºC | ||||
Humidity range | >65%R·H | ||||
Ozone concentration |
0-200PPm.0-300PPm | ||||
Temperature fluctuation |
±0.5ºC | ||||
test apparatus |
Dynamic and static (optional) |
||||
Sample rack rotation speed |
360 degree rotating sample holder (1 rpm per minute) |
||||
Gas flow rate |
12-16mm/s | ||||
Temperature Controller |
Imported LED digital display P.L. D+5.5, R microcomputer integrated controller |
||||
Time controller |
Precision hours,minutes,seconds time controller |
||||
Ozone concentration analysis |
Imported concentration analysis regulator 4-20mA outputs,RS232 communication port |
||||
Ozone generator |
Silent discharge tube type |
||||
Security protection |
Leakoge,short circuit,over temperature,motor overheating.over-current protection |